ver:"3.0" def,accumulate,baseUri,children,childrenFlatten,computedFromReciprocal,containedBy,depends,dis,doc,docAssociations,docTaxonomy,enum,fileExt,inputs,is,lib,mandatory,maxVal,mime,minVal,noSideEffects,notInherited,of,openEnum,prefUnit,quantityOf,reciprocalOf,tagOn,transient,transitive,version,wikipedia ^absorption,,,,,,,,,"Cooling process using energy from heat source such as hot water",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Absorption_refrigerator` ^ac,,,,,,,,,"Relating to alternating current electricity",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^ac-elec,,,,,,,,,"Alternating current electricity",,,,,,[^elec],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Alternating_current` ^ac-elec-meter,,,[{avg ac elec current angle sensor point},{avg ac elec current imbalance sensor point},{avg ac elec current magnitude sensor point},{avg ac elec current thd sensor point},{avg ac elec pf sensor point},{avg ac elec volt angle sensor point},{avg ac elec volt imbalance sensor point},{avg ac elec volt magnitude sensor point},{avg ac elec volt thd sensor point},{equip},{phase:"A" ac elec current angle sensor point},{phase:"A" ac elec current imbalance sensor point},{phase:"A" ac elec current magnitude sensor point},{phase:"A" ac elec current thd sensor point},{phase:"A" ac elec pf sensor point},{phase:"A" ac elec volt angle sensor point},{phase:"A" ac elec volt imbalance sensor point},{phase:"A" ac elec volt magnitude sensor point},{phase:"A" ac elec volt thd sensor point},{phase:"A" active ac elec power sensor point},{phase:"A" apparent ac elec power sensor point},{phase:"A" net ac elec active energy sensor point},{phase:"A" reactive ac elec power sensor point},{point},{total ac elec demand sensor point},{total active ac elec power sensor point},{total apparent ac elec power sensor point},{total export ac elec active energy sensor point},{total import ac elec active energy sensor point},{total net ac elec active energy sensor point},{total reactive ac elec power sensor point}],,,,,,"AC Electricity meter.\nSee `docHaystack::Meters` chapter.",,,,,,[^elec-meter],^lib:phIoT,,,,,,,,,,,,,,,, ^ac-evse-port,,,[{dc elec stateOfCharge sensor point},{equip},{evse cable equip},{evse evseStatus sensor point},{import ac elec active energy hisTotalized sensor point},{import ac elec active power max sp point},{import ac elec active power sensor point},{import ac elec magnitude current max sp point},{import ac elec magnitude current sensor point},{import ac elec magnitude volt sensor point},{import ac elec pfScope pf sensor point},{point}],,,,,,"An AC EVSE port delivers `ac` electricity to a single EV charging inlet\nat a time. See `docHaystack::EVSE#port` chapter.\n\nTypically a max current or max power setpoint should reference an AC\nEVSE port, but not both. Usually it is preferred to control an AC EVSE\nport using a max current setpoint.\n\nIt is recommended to include electrical location related tags on\nelectrical points that reference an AC EVSE port. See\n`docHaystack::Meters#elecMeters` chapter for more details.",,,,,,[^evse-port],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Charging_station` ^ac-freq,,,,,,,,,"Frequency of alternating current",,,,,,[^freq],^lib:phIoT,,,,,,,,,["Hz"],[^ac-elec],,,,,, ^accumulate,,,,,,,,,"Accumulate the tag's value during [inheritance]`docHaystack::Normalization#inherit`\nand [defx]`docHaystack::Normalization#defx`. Tags marked as accumulate\nare aggregated together during normalization and deduplicated. This\nmarker must only be used on tags which expect a list value.",,,,,,[^marker],^lib:ph,,,,,,,,,,,,,,,, ^active,,,,,,,,,"Working, operative, effective",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^active-energy,,,,,,,,,"Integral of `active-power` over time",,,,,,[^elec-energy],^lib:phIoT,,,,,,,,,["kWh"],[^ac-elec],,,,,, ^active-power,,,,,,,,,"Active power or real power; energy transfer that contributes useful work",,,,,,[^elec-power],^lib:phIoT,,,,,,,,,["kW"],[^ac-elec],,,,,, ^actuator,,,[{equip},{point}],,,,,,"Equipment to move or control a mechanism. Actuators may be manually\noperated or automated via a control system to convert an energy source\ninto mechanical energy. Typically the energy source is electricity,\nhydraulics, or pneumatics.",,,,,,[^equip,^elec-input],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Actuator` ^ahu,,,[{bypass damper cmd point},{cool cmd point},{dessicantDehumidifier cmd point},{discharge duct equip},{economizer duct equip},{economizing cmd point},{equip},{exhaust duct equip},{faceBypass cmd point},{filter sensor point},{freezeStat sensor point},{heat cmd point},{heatWheel cmd point},{humidifier equip},{hvacMode sp point},{mixed duct equip},{outside duct equip},{point},{return duct equip},{thermostat equip},{ventilation duct equip}],,,,,,"Air Handling Unit: An enclosure with a fan that delivers air to a space\nvia ductwork and performs one or more of the functions of cleaning,\nheating, cooling, humidifying, dehumidifying, ventilating or circulating\nthe air. See `docHaystack::AHUs` chapter.",,,,,,[^airHandlingEquip],^lib:phIoT,M,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Air_handler` ^ahuZoneDelivery,,,,,,,,,"AHU delivery method of conditioned air to the zone",,,,,,[^choice],^lib:phIoT,,,,,,,,,,,,[^airHandlingEquip],,,, ^air,,,,,,,,,"The mixture of gases which surrounds the earth",,,,,,[^gas],^lib:phScience,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Atmosphere_of_Earth` ^air-conditioning-system,,,[{equip},{point}],,,,,,"System for air treatment to control its temperature, humidity, cleanliness,\nand distribution to meet the requirements of a conditioned space.",,,,,,[^air-system],^lib:phIoT,,,,,,,,,,,,,,,, ^air-exhaust-system,,,[{equip},{point}],,,,,,"System consisting of one or more fans that remove air from the building.\nExhaust systems allow outdoor air to enter by ventilation inlets or normal\nleakage paths sthrough the building envelope.",,,,,,[^air-system],^lib:phIoT,,,,,,,,,,,,,,,, ^air-input,,,,,,,,,"Entity inputs air which flows from another entity",,,,,,[^input],^lib:phIoT,,,,,,,,,,,,,,,, ^air-output,,,,,,,,,"Entity outputs air to other entities",,,,,,[^output],^lib:phIoT,,,,,,,,,,,,,,,, ^air-system,,,[{equip},{point}],,,,,,"System for moving air to maintain indoor thermal comfort and/or air quality.",,,,,,[^system],^lib:phIoT,,,,,,,,,,,,,,,, ^air-temp,,,,,,,,,"Dry bulb temperature",,,,,,[^temp],^lib:phScience,,,,,,,,,["°C","°F"],[^air],,,,,,`https://en.wikipedia.org/wiki/Temperature` ^air-velocity,,,,,,,,,"Rate of air movement as distance over time",,,,,,[^quantity],^lib:phScience,,,,,,,,,["m/sec","ft/min"],[^air],,,,,, ^air-ventilation-system,,,[{equip},{point}],,,,,,"System that supplies or removes air by natural or mechanical means to or\nfrom any space in order to provide outdoor air to the space. Such air may or\nmay not have been conditioned.",,,,,,[^air-system],^lib:phIoT,,,,,,,,,,,,,,,, ^airCooling,,,,,,,,,"Cooling by dissipating heat into the surrounding air",,,,,,[^coolingProcess,^air-input],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Air_cooling` ^airHandlingEquip,,,[{bypass damper cmd point},{cool cmd point},{dessicantDehumidifier cmd point},{discharge duct equip},{economizer duct equip},{economizing cmd point},{equip},{exhaust duct equip},{faceBypass cmd point},{filter sensor point},{freezeStat sensor point},{heat cmd point},{heatWheel cmd point},{humidifier equip},{hvacMode sp point},{mixed duct equip},{outside duct equip},{point},{return duct equip},{thermostat equip},{ventilation duct equip}],,,,,,"HVAC equipment that conditions and delivers air via one or more fans.\nConditioning of air includes heating, cooling, humidification,\ndehumidification, and ventilation. See `docHaystack::AHUs` chapter.",,,,,,[^equip,^air-output,^elec-input],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Air_handler` ^airQuality,,,,,,,,,"Concentration of contaminants in the air",,,,,,[^concentration],^lib:phScience,,,,,,,,,,[^air],,,,,,`https://en.wikipedia.org/wiki/Concentration` ^airQualityZonePoints,,,[{zone air ch2o concentration sensor point},{zone air co concentration sensor point},{zone air co2 concentration sensor point},{zone air co2 concentration sp point},{zone air nh3 concentration sensor point},{zone air no2 concentration sensor point},{zone air o3 concentration sensor point},{zone air pm01 concentration sensor point},{zone air pm10 concentration sensor point},{zone air pm25 concentration sensor point},{zone air tvoc concentration sensor point}],,,,,,"Entity with logical grouping of zone air quality points.\nSee `docHaystack::Zones#airQuality` chapter.",,,,,,[^pointGroup],^lib:phIoT,,,,,,,,,,,,,,,, ^airRef,,,,,,,,,"Air flows from the referent to this entity",,,,,^air,[^ref],^lib:phIoT,,,,,,,^air-output,,,,,[^air-input],,,, ^airTerminalUnit,,,[{discharge duct equip},{equip},{inlet duct equip},{point},{thermostat equip}],,,,,,"Equipment in air distribution systems which terminate at the space.\nTerminal units receive air from `airHandlingEquip` which have the\nprimarily responsibility to condition air. Terminal units are primarily\nresponsible for delivery of air to the space and tempering the temperature.",,,,,,[^equip,^air-input,^air-output,^elec-input],^lib:phIoT,,,,,,,,,,,,,,,, ^airVolumeAdjustability,,,,,,,,,"Ability of air handling equip to adjust volume of air flow",,,,,,[^choice],^lib:phIoT,,,,,,,,,,,,[^airHandlingEquip],,,, ^alarm,,,,,,,,,"Notification of a condition which requires attention",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^angle,,,,,,,,,"Measurement of the relative difference in direction between two vectors or phasors",,,,,,[^marker],^lib:phScience,,,,,,,,,,,,,,,, ^apparent,,,,,,,,,"Perceived quantity",,,,,,[^marker],^lib:phScience,,,,,,,,,,,,,,,, ^apparent-energy,,,,,,,,,"Integral of `apparent-power` over time",,,,,,[^quantity],^lib:phIoT,,,,,,,,,,[^ac-elec],,,,,, ^apparent-power,,,,,,,,,"Apparent power is perceived magnitude of power due to the combination of active and reactive power",,,,,,[^quantity],^lib:phIoT,,,,,,,,,["kVA"],[^ac-elec],,,,,, ^area,,,,,,,,,"Area of a shape or floor space",,,,,,[^number],^lib:phIoT,,,,,,,,,["ft²","m²"],,,[^site,^space],,,, ^association,,,,,,,,,"Associations model ontological relationships between definitions.\nSee [Associations]`docHaystack::Associations` chapter.",,M,,,,[^list],^lib:ph,,,,,,,^symbol,,,,,,,,, ^ates,,,[{cool water flow thermal meter equip},{cool well equip},{equip},{extraction well equip},{flowInverter equip},{ground water flow sensor point},{ground water pressure sensor point},{ground water volume sensor point},{heatExchanger equip},{infiltration well equip},{point},{purge water flow sensor point},{purge water volume sensor point},{warm water flow thermal meter equip},{warm well equip}],,,,,,"Aquifer Thermal Energy Storage system.\nSee `docHaystack::ATES` chapter.",,,,,,[^equip],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Aquifer_thermal_energy_storage` ^atesClosedLoop,,,,,,,,,"The ATES uses closed piping to transport a water/glycol mixture\nthrough the ground. The system works like a heat exchanger; there\nis no ground water transported.",,,,,,[^atesDesign],^lib:phIoT,,,,,,,,,,,,,,,, ^atesDesign,,,,,,,,,"Design type of the ATES underground system.",,,,,,[^choice],^lib:phIoT,,,,,,,,,,,,[^ates],,,, ^atesDoublet,,,,,,,,,"The ATES has one or more pairs of a separate warm and cool well.",,,,,,[^atesDesign],^lib:phIoT,,,,,,,,,,,,,,,, ^atesDoubletPaired,,,,,,,,,"The ATES is as a doublet, but with specific warm and cool wells linked together.\nThese linked wells do not exchange water with other wells.",,,,,,[^atesDesign],^lib:phIoT,,,,,,,,,,,,,,,, ^atesMono,,,,,,,,,"The ATES has only one physical well. This well is deep enough\nto penetrate two layers of groundwater.",,,,,,[^atesDesign],^lib:phIoT,,,,,,,,,,,,,,,, ^atesUnidirectional,,,,,,,,,"Similar to a doublet, but water always flows in the same direction from\nthe extraction to the infiltration well.",,,,,,[^atesDesign],^lib:phIoT,,,,,,,,,,,,,,,, ^atmospheric,,,,,,,,,"Related to the atmosphere of the earth",,,,,,[^marker],^lib:phScience,,,,,,,,,,,,,,,, ^atmospheric-pressure,,,,,,,,,"Barometric pressure exerted by the weight of the atmosphere",,,,,,[^pressure],^lib:phScience,,,,,,,,,["millibar","inHg"],[^weather],,,,,,`https://en.wikipedia.org/wiki/Pressure` ^avg,,,,,,,,,"Average; central or typical value; median",,,,,,[^marker],^lib:phScience,,,,,,,,,,,,,,,, ^bacnet,,,,,,,,,"ASHRAE building automation and control protocol",,,,,,[^protocol],^lib:phIct,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/BACnet` ^barometric,,,,,,,,,"Relating atmospheric pressure",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^baseUri,,,,,,,,,"Base URI for normalizing relative URIs",,,,,,[^uri],^lib:ph,,,,,,,,,,,,[^lib],,,, ^battery,,,[{equip},{point}],,,,,,"Equipment used to store electric energy",,,,,,[^equip,^elec-output],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Electric_battery` ^biomass,,,,,,,,,"Plant or animal material used as fuel to produce electricity or heat",,,,,,[^substance],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Biomass` ^biomassHeating,,,,,,,,,"Heating by the combustion of biomass",,,,,,[^heatingProcess],^lib:phIoT,,,,,,,,,,,,,,,, ^blowdown,,,,,,,,,"Removal from container or pipe",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^blowdown-water,,,,,,,,,"Water expelled from a system to remove mineral build up",,,,,,[^water],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Water` ^blowdown-water-input,,,,,,,,,"Entity inputs blowdown water which flows from another entity",,,,,,[^input],^lib:phIoT,,,,,,,,,,,,,,,, ^blowdown-water-output,,,,,,,,,"Entity outputs blowdown water to other entities",,,,,,[^output],^lib:phIoT,,,,,,,,,,,,,,,, ^blowdownWaterRef,,,,,,,,,"Blowdown water flows from the referent to this entity",,,,,^blowdown-water,[^ref],^lib:phIoT,,,,,,,^blowdown-water-output,,,,,[^blowdown-water-input],,,, ^bluetooth,,,,,,,,,"Short range wireless communication protocol",,,,,,[^protocol],^lib:phIct,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Bluetooth` ^boiler,,,[{alarm sensor point},{equip},{point}],,,,,,"Equipment to generate hot water or steam for heating",,,,,,[^equip,^elec-input],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Boiler` ^bool,,,,,,,,,"Boolean value 'true' or 'false'.\nSee [Kinds chapter]`docHaystack::Kinds#bool`.",,,,,,[^scalar],^lib:ph,,,,,,,,,,,,,,,, ^branchSelector,,,[{equip},{point}],,,,,,"Branch selector used for heat recovery in a VRF system. These are\ncontrol devices directing the liquid refrigerant or gas refrigerant\nto zones requiring cooling or heating. See `docHaystack::VRF#branchSelector`\nchapter.",,,,,,[^vrf-equip,^refrig-input],^lib:phIoT,,,,,,,,,,,,,,,, ^bypass,,,,,,,,,"Pipe used to bypass an equipment",,,,,,[^pipeSection],^lib:phIoT,,,,,,,,,,,,,,,, ^cable,,,[{equip},{point}],,,,,,"An assembly of one or more insulated conductors.",,,,,,[^equip],^lib:phIoT,,,,,,,,,,,,,,,, ^cav,,,[{discharge duct equip},{equip},{inlet duct equip},{point},{thermostat equip}],,,,,,"Constant air volume terminal unit. CAV systems use a constant\nair flow rate with a variable air temperature.",,,,,,[^airTerminalUnit],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Constant_air_volume` ^centrifugal,,,,,,,,,"Compression via a continuous flow of fluid through an impeller",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Centrifugal_compressor` ^ch2o,,,,,,,,,"Formaldehyde (CH₂O)",,,,,,[^gas],^lib:phScience,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Formaldehyde` ^ch2o-concentration,,,,,,,,,"Concentration of formaldehyde (CH₂O) in the air.",,,,,,[^airQuality],^lib:phScience,,,,,,,,,["µg/m³","ppb"],[^air],,,,,,`https://en.wikipedia.org/wiki/Concentration` ^ch4,,,,,,,,,"Methane (CH₄)",,,,,,[^gas],^lib:phScience,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Methane` ^ch4-emission,,,,,,,,,"Greenhouse gas emission of methane (CH₄) into the air.",,,,,,[^emission],^lib:phScience,,,,,,,,,["kg","ton","lb"],[^air],,,,,, ^children,M,,,,,,,,"List of prototypes contained by this entity.\nSee [Protos chapter]`docHaystack::Protos` for more details.",,,,,,[^list],^lib:ph,,,,,,,^dict,,,,,,,,, ^childrenFlatten,,,,,,,,,"List of aspects to flatten into children prototypes.\nSee [Protos chapter]`docHaystack::Protos` for more details.",,,,,,[^list],^lib:ph,,,,,,,^symbol,,,,,,,,, ^chilled,,,,,,,,,"Substance is cooled using cooling process",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^chilled-water,,,,,,,,,"Water cooled for use in HVAC and industrial processes",,,,,,[^water],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Chilled_water` ^chilled-water-input,,,,,,,,,"Entity inputs chilled water which flows from another entity",,,,,,[^input],^lib:phIoT,,,,,,,,,,,,,,,, ^chilled-water-output,,,,,,,,,"Entity outputs chilled water to other entities",,,,,,[^output],^lib:phIoT,,,,,,,,,,,,,,,, ^chilled-water-plant,,,[{chilled water bypass pipe equip},{chilled water delta flow point},{chilled water delta pressure point},{chilled water delta temp point},{chilled water entering pipe equip},{chilled water header pipe equip},{chilled water heatExchanger equip},{chilled water leaving pipe equip},{chilled water mixing valve cmd point},{chiller equip},{condenser water bypass pipe equip},{condenser water delta flow sensor point},{condenser water delta pressure sensor point},{condenser water delta temp sensor point},{coolingTower equip},{enable cmd point},{equip},{point}],,,,,,"Plant used to generate chilled water for cooling.\nSee `docHaystack::Plants`.",,,,,,[^plant,^chilled-water-output],^lib:phIoT,,,,,,,,,,,,,,,, ^chilled-water-system,,,[{equip},{point}],,,,,,"System that circulates water in its liquid state below ambient temperature\nfor cooling a space or process.",,,,,,[^water-system],^lib:phIoT,,,,,,,,,,,,,,,, ^chilledBeam,,,[{equip},{point}],,,,,,"Conditions a space using a heat exchanger integrated into the ceiling",,,,,,[^radiantEquip],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Chilled_beam` ^chilledBeamZone,,,,,,,,,"AHU supplies air to chilled beam terminal units",,,,,,[^ahuZoneDelivery],^lib:phIoT,,,,,,,,,,,,,,,, ^chilledWaterCooling,,,,,,,,,"Cooling using transfer of heat to chilled water",,,,,,[^coolingProcess,^chilled-water-input],^lib:phIoT,,,,,,,,,,,,,,,, ^chilledWaterRef,,,,,,,,,"Chilled water flows from the referent to this entity",,,,,^chilled-water,[^ref],^lib:phIoT,,,,,,,^chilled-water-output,,,,,[^chilled-water-input],,,, ^chiller,,,[{alarm sensor point},{chilled water delta flow sensor point},{chilled water delta temp sensor point},{chilled water entering pipe equip},{chilled water leaving pipe equip},{chilled water valve isolation cmd point},{condenser refrig pressure sensor point},{condenser refrig temp sensor point},{condenser run cmd point},{condenser run sensor point},{condenser water entering pipe equip},{condenser water leaving pipe equip},{condenser water valve isolation cmd point},{efficiency sensor point},{enable cmd point},{enable sensor point},{equip},{evaporator refrig pressure sensor point},{evaporator refrig temp sensor point},{load cmd point},{load sensor point},{point},{run cmd point},{run sensor point}],,,,,,"Equipment to remove heat from a liquid. Chillers typically use a vapor\ncompression or an absorption refrigeration cycle.",,,,,,[^equip,^elec-input],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Chiller` ^chiller-absorption,,,,,,,,,"Cooling process using energy from heat source such as hot water",,,,,,[^absorption,^chillerMechanism],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Absorption_refrigerator` ^chiller-centrifugal,,,,,,,,,"Compression via a continuous flow of fluid through an impeller",,,,,,[^centrifugal,^chillerMechanism],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Centrifugal_compressor` ^chiller-reciprocal,,,,,,,,,"Piston compressor driven by a crankshaft",,,,,,[^reciprocal,^chillerMechanism],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Reciprocating_compressor` ^chiller-rotaryScrew,,,,,,,,,"Rotary screw compression",,,,,,[^rotaryScrew,^chillerMechanism],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Rotary-screw_compressor` ^chillerMechanism,,,,,,,,,"Primary mechanism of chiller",,,,,,[^choice],^lib:phIoT,,,,,,,,,,,,[^chiller],,,, ^choice,,,,,,,,,"Choice specifies an exclusive marker selection.\nSee [Choices]`docHaystack::Choices` chapter.",,M,,,,[^marker],^lib:ph,,,,,,,,,,,,,,,, ^circ,,,,,,,,,"Pipe used to circulate fluid through an equipment or system",,,,,,[^pipeSection],^lib:phIoT,,,,,,,,,,,,,,,, ^circuit,,,[{equip},{point}],,,,,,"Electrical circuit and its associated components such as breakers.\nSee `docHaystack::ElecPanels#circuits` chapter.",,,,,,[^equip,^elec-input,^elec-output],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Electrical_network` ^cloudage,,,,,,,,,"Percentage of sky obscured by clouds. This is also known as cloudiness, or cloud amount.",,,,,,[^quantity],^lib:phScience,,,,,,,,,["%"],[^weather],,,,,, ^cmd,,,,,,,,,"Point is a command, actuator, AO/BO.\nSee `docHaystack::Points#function` chapter.",,,,,,[^pointFunction],^lib:phIoT,,,,,,,,,,,,,,,, ^co,,,,,,,,,"Carbon monoxide (CO)",,,,,,[^gas],^lib:phScience,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Carbon_monoxide` ^co-concentration,,,,,,,,,"Concentration of carbon monoxide (CO) in the air.",,,,,,[^airQuality],^lib:phScience,,,,,,,,,["ppm"],[^air],,,,,,`https://en.wikipedia.org/wiki/Concentration` ^co2,,,,,,,,,"Carbon dioxide (CO₂)",,,,,,[^gas],^lib:phScience,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Carbon_dioxide` ^co2-concentration,,,,,,,,,"Concentration of carbon dioxide (CO₂) in the air.",,,,,,[^airQuality],^lib:phScience,,,,,,,,,["ppm"],[^air],,,,,,`https://en.wikipedia.org/wiki/Concentration` ^co2-emission,,,,,,,,,"Greenhouse gas emission of carbon dioxide (CO₂) into the air.",,,,,,[^emission],^lib:phScience,,,,,,,,,["kg","ton","lb"],[^air],,,,,, ^co2e,,,,,,,,,"Carbon dioxide equivalent",,,,,,[^marker],^lib:phScience,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Global_warming_potential` ^coal,,,,,,,,,"Combustible sedimentary rock",,,,,,[^solid],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Coal` ^coalHeating,,,,,,,,,"Heating by the combustion of coal",,,,,,[^heatingProcess],^lib:phIoT,,,,,,,,,,,,,,,, ^coap,,,,,,,,,"Constrained Application Protocol",,,,,,[^protocol],^lib:phIct,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Constrained_Application_Protocol` ^coil,,,[{equip},{point}],,,,,,"Heat exchanger used to heat or cool air. Coils are sub-components\nof HVAC equipment such as `airHandlingEquip`.",,,,,,[^heatExchanger],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Heat_exchanger#HVAC_air_coils` ^cold,,,,,,,,,"Having low degree of heat",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^cold-water,,,,,,,,,"Water supplied to cold taps",,,,,,[^water],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Water` ^coldDeck,,,,,,,,,"Duct carries air for cooling",,,,,,[^ductDeck],^lib:phIoT,,,,,,,,,,,,,,,, ^compressor,,,,,,,,,"Device for mechanically increasing the pressure of a gas or refrigerant\nvapor by reducing its volume.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^computed,,,,,,,,,"Computed point. See `docHaystack::Synthetics` chapter.",,,,,,[^synthetic],^lib:phIoT,,,,,,,,,,,,,,,, ^computed-point,,,,,,,,,"See `docHaystack::Synthetics` chapter.",,,,,,[^synthetic-point],^lib:phIoT,,,,,,,,,,,,,,,, ^computedFromReciprocal,,,,,,,,,"Indicates a relationship that is computed from its reciprocal.\nComputed defs cannot be used as tags themselves.",,,,,,[^marker],^lib:ph,,,,,,,,,,,,,,,, ^computedModel,,,,,,,,,"See `docHaystack::Synthetics` chapter.",,,,,,[^syntheticModel],^lib:phIoT,,,,,,,,,,,,,,,, ^computer,,,,,,,,,"General purpose computer.",,,,,,[^device],^lib:phIct,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Computer` ^concentration,,,,,,,,,"Abundance of substance in the total volume of a mixture.",,,,,,[^quantity],^lib:phScience,,,,,,,,,,[^substance],,,,,,`https://en.wikipedia.org/wiki/Concentration` ^condensate,,,,,,,,,"Liquid phase produced by the condensation of steam or other gas",,,,,,[^liquid],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Liquid` ^condensate-input,,,,,,,,,"Entity inputs condensate which flows from another entity",,,,,,[^input],^lib:phIoT,,,,,,,,,,,,,,,, ^condensate-output,,,,,,,,,"Entity outputs condensate to other entities",,,,,,[^output],^lib:phIoT,,,,,,,,,,,,,,,, ^condensateRef,,,,,,,,,"Condensate flows from the referent to this entity",,,,,^condensate,[^ref],^lib:phIoT,,,,,,,^condensate-output,,,,,[^condensate-input],,,, ^condenser,,,,,,,,,"Device or related to process of condensation",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^condenser-water,,,,,,,,,"Water used used to remove heat through condensation",,,,,,[^water],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Water` ^condenser-water-input,,,,,,,,,"Entity inputs condenser water which flows from another entity",,,,,,[^input],^lib:phIoT,,,,,,,,,,,,,,,, ^condenser-water-output,,,,,,,,,"Entity outputs condenser water to other entities",,,,,,[^output],^lib:phIoT,,,,,,,,,,,,,,,, ^condenser-water-system,,,[{equip},{point}],,,,,,"System that circulates water in its liquid state for rejecting heat\nfrom a space or process.",,,,,,[^water-system],^lib:phIoT,,,,,,,,,,,,,,,, ^condenserClosedLoop,,,,,,,,,"Working fluid is kept separate from fluid used for heat transfer into the atmosphere",,,,,,[^condenserLoop],^lib:phIoT,,,,,,,,,,,,,,,, ^condenserCooling,,,,,,,,,"Removal of heat through the process of water condensation",,,,,,[^coolingProcess],^lib:phIoT,,,,,,,,,,,,,,,, ^condenserLoop,,,,,,,,,"Open or closed loop for condenser working fluid",,,,,,[^choice],^lib:phIoT,,,,,,,,,,,,[^chilled-water-plant],,,, ^condenserOpenLoop,,,,,,,,,"Uses working fluid itself for evaporation into the atmosphere",,,,,,[^condenserLoop],^lib:phIoT,,,,,,,,,,,,,,,, ^condenserWaterRef,,,,,,,,,"Condenser water flows from the referent to this entity",,,,,^condenser-water,[^ref],^lib:phIoT,,,,,,,^condenser-water-output,,,,,[^condenser-water-input],,,, ^conditioning,,,,,,,,,"Related to cleaning, heating, cooling, humidifying, dehumidifying,\nventilating or circulating air. ",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^conduit,,,[{equip},{point}],,,,,,"Duct, pipe, or cable to convey a substance or phenomenon",,,,,,[^equip],^lib:phIoT,,,,,,,,,,,,,,,, ^constantAirVolume,,,,,,,,,"Delivers a constant volume of air flow. Typically this means\nequipment with a single speed fan.",,,,,,[^airVolumeAdjustability],^lib:phIoT,,,,,,,,,,,,,,,, ^containedBy,,,,,,,,,"The entity is logically contained by the referent.",,,,,,[^relationship],^lib:ph,,,,,,,,,,,^contains,,,M,, ^contains,,,,,M,,,,"Entities logically contained by this entity",,,,,,[^relationship],^lib:ph,,,,,,,,,,,^containedBy,,,M,, ^controller,,,,,,,,,"Microprocessor based device used in a control system. Controllers\ninteract with the physical world through direct I/O to sensors and\nactuators or via network [protocols]`protocol`.",,,,,,[^device],^lib:phIct,,,,,,,,,,,,,,,, ^controls,,,,,,,,,"Associated with the control system for an industrial process",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Control_system` ^controls-panel,,,[{controller device},{equip},{networking device},{point}],,,,,,"Panel housing controllers and networking gear",,,,,,[^panel],^lib:phIct,,,,,,,,,,,,,,,, ^cool,,,,,,,,,"Associted with low temperature or cooling processes. When used on a point,\nthis tag is associated with the control of cooling. When paired with a\nsubstance, this tag indicates the substance is relatively cool in comparison\nto another substance, without being actively cooled by e.g. a chiller.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^cool-water,,,,,,,,,"Relatively cool water without active chilling",,,,,,[^water],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Water` ^cooling,,,,,,,,,"Cooling mode or process",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^coolingCapacity,,,,,,,,,"Measurement of a chiller ability to remove heat measured",,,,,,[^number],^lib:phIoT,,,,,,,,,["tonref","BTU/h","kW"],,,[^chiller],,,, ^coolingCoil,,,[{chilled water cool valve cmd point},{equip},{point},{stage:1 cool run cmd point}],[^ductDeck,^ductSection],,,,,"Coil used to cool air.",,,,,,[^coil],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Heat_exchanger#HVAC_air_coils` ^coolingOnly,,,,,,,,,"Equipment without heating",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^coolingProcess,,,,,,,,,"Processed used to cool a substance",,,,,,[^choice],^lib:phIoT,,,,,,,,,,,,[^airHandlingEquip,^chilledBeam,^coolingCoil],,,, ^coolingTower,,,[{condenser water entering pipe equip},{condenser water leaving pipe equip},{equip},{fan motor equip},{point}],,,,,,"Equipment to transfer waste heat into the atmosphere",,,,,,[^equip,^elec-input],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Cooling_tower` ^coord,,,,,,,,,"Geographic coordinate in latitude/longitude in decimal degrees.\nSee [Kinds chapter]`docHaystack::Kinds#coord`.",,,,,,[^scalar],^lib:ph,,,,,,,,,,,,,,,, ^crac,,,[{bypass damper cmd point},{cool cmd point},{dessicantDehumidifier cmd point},{discharge duct equip},{economizer duct equip},{economizing cmd point},{equip},{exhaust duct equip},{faceBypass cmd point},{filter sensor point},{freezeStat sensor point},{heat cmd point},{heatWheel cmd point},{humidifier equip},{hvacMode sp point},{mixed duct equip},{outside duct equip},{point},{return duct equip},{thermostat equip},{ventilation duct equip}],,,,,,"Computer Room Air Conditioner: An FCU designed to condition a computer\nroom. See `docHaystack::AHUs` and `docHaystack::DataCenters` chapters.",,,,,,[^fcu],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Fan_coil_unit` ^cur,,,,,,,,,"Supports current value",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,[^point],,,, ^cur-point,,,,,,,,,"Point with support to report a \"real-time\" current value. By real-time\nwe typically mean freshness within the order of a few seconds or at\nmost a few minutes. For systems with direct I/O the current value is\ntypically driven by the I/O scan rate. For overlay systems which acquire\ndata via a protocol such as BACnet or Modbus then the current value\nis typically refreshed using polling or subscription over a network.\nAlso see `docHaystack::Points#cur` chapter.",,,,,,[^point],^lib:phIoT,,,,,,,,,,,,,,,, ^curErr,,,,,,,,,"Error description when `curStatus` indicates error condition",,,,,,[^str],^lib:phIoT,,,,,,,,,,,,[^cur-point],M,,, ^curStatus,,,,,,,,,"Status of point's current value reading. The `curVal` is only available\nwhen curStatus is \"ok\" or \"stale\". However a \"stale\" value should\nbe used with caution since the local system does not have a fresh value.\nIt is recommended that the `curVal` tag is removed from a point\nwhen the curStatus is not \"ok\" nor \"stale\".",,,"- ok: all is okay\n- stale: the point's curVal is not fresh data\n- fault: a configuration or hardware problem - see `curErr`\n- down: a communication or network problem - see `curErr`\n- disabled: manual disable of the point or connector\n- unknown: we don't know anything (usually boot state)\n- remoteFault: point in remote system is fault\n- remoteDown: point in remote system is down\n- remoteDisabled: point in remote system is disabled\n- remoteUnknown: point in remote system is unknown",,,[^str],^lib:phIoT,,,,,,,,,,,,[^cur-point],M,,, ^curVal,,,,,,,,,"Current value of a point. The current value is only available when\nthe `curStatus` is \"ok\" or \"stale\".",,,,,,[^scalar],^lib:phIoT,,,,,,,,,,,,[^cur-point],M,,, ^current,,,,,,,,,"Movement of fluid or electricity",,,,,,[^marker],^lib:phScience,,,,,,,,,,,,,,,, ^current-angle,,,,,,,,,"AC current phase angle",,,,,,[^quantity],^lib:phIoT,,,,,,,,,["deg"],[^ac-elec],,,,,, ^current-imbalance,,,,,,,,,"Current phase imbalance in a multiphase AC system",,,,,,[^quantity],^lib:phIoT,,,,,,,,,["%"],[^ac-elec],,,,,, ^current-magnitude,,,,,,,,,"Magnitude of electrical current",,,,,,[^elec-current],^lib:phIoT,,,,,,,,,["A"],[^ac-elec],,,,,, ^current-thd,,,,,,,,,"Total harmonic current distortion",,,,,,[^quantity],^lib:phIoT,,,,,,,,,["%"],[^ac-elec],,,,,, ^dali,,,,,,,,,"Digital Addressable Lighting Interface protocol for lighting",,,,,,[^protocol],^lib:phIct,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Digital_Addressable_Lighting_Interface` ^damper,,,,,,,,,"Damper equipment or control point.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Damper_(flow)` ^damper-actuator,,,[{damper cmd point},{damper sensor point},{equip},{point}],[^ductSection],,,,,"Actuator to regulate the flow of air.",,,,,,[^actuator],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Damper_(flow)` ^dataCenter,,,[{crac fcu equip},{equip},{point},{rack equip},{space}],,,,,,"Space used to house computer and networking gear.\nSee `docHaystack::DataCenters` chapter.",,,,,,[^space],^lib:phIct,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Data_center` ^date,,,,,,,,,"ISO 8601 date as year, month, day: '2011-06-07'.\nSee [Kinds chapter]`docHaystack::Kinds#date`.",,,,,,[^scalar],^lib:ph,,,,,,,,,,,,,,,, ^dateTime,,,,,,,,,"ISO 8601 timestamp followed by timezone identifier.\nSee [Kinds chapter]`docHaystack::Kinds#dateTime`.",,,,,,[^scalar],^lib:ph,,,,,,,,,,,,,,,, ^daytime,,,,,,,,,"Time between sunrise and sunset",,,"- nighttime: false indicates sun is below horizon\n- daytime: true indicates sun is above horizon",,,[^quantity],^lib:phScience,,,,,,,,,,[^weather],,,,,, ^dc,,,,,,,,,"Relating to direct current electricity",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^dc-elec,,,,,,,,,"Direct current electricity",,,,,,[^elec],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Direct_current` ^dc-elec-meter,,,[{equip},{point}],,,,,,"DC Electricity meter.\nSee `docHaystack::Meters` chapter.",,,,,,[^elec-meter],^lib:phIoT,,,,,,,,,,,,,,,, ^dc-evse-port,,,[{dc elec stateOfCharge sensor point},{equip},{evse cable equip},{evse evseStatus sensor point},{import dc elec current max sp point},{import dc elec current sensor point},{import dc elec energy hisTotalized sensor point},{import dc elec power max sp point},{import dc elec power sensor point},{import dc elec volt sensor point},{point}],,,,,,"A DC EVSE port delivers `dc` electricity to a single EV charging inlet\nat a time. See `docHaystack::EVSE#port` chapter.\n\nTypically a max current or max power setpoint should reference a DC\nEVSE port, but not both. Usually it is preferred to control a DC EVSE\nport using a max power setpoint.",,,,,,[^evse-port],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Charging_station` ^deadband,,,,,,,,,"The range in a process where no changes to output are made.\nMay also indicate the difference between a base setpoint and effective\nsetpoint.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^def,,,,,,,,,"Create a new definition bound to the given symbol.\nSee [Defs chapter]`docHaystack::Defs`.",,,,,,[^symbol],^lib:ph,,,,,,,,,,,,,,,, ^defx,,,,,,,,,"Extends the given definition with additional meta tags.\nSee [Normalization]`docHaystack::Normalization#defx`.",,,,,,[^symbol],^lib:ph,,,,,,,,,,,,,,,, ^delta,,,,,,,,,"Differential of fluid between entering and leaving sensors.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^demand,,,,,,,,,"Rate required for a process.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^depends,,,,,,,,,"List of this library's dependencies. The dependent libs define the\n[lib namespace]`docHaystack::Namespaces#lib`. Also see\n[Normalization]`docHaystack::Normalization#resolve`.",,,,,,[^list],^lib:ph,,,,,,,^ref,,,,,[^lib],,,, ^deprecated,,,,,,,,,"Obsoleted",,,,,,[^marker],^lib:ph,,,,,,,,,,,,,,,, ^design,,,,,,,,,"Data related to intended design and operating conditions. This\nincludes sizing and other data specified by design engineers and\nengineered drawings. Also see `rated`.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^dessicantDehumidifier,,,,,,,,,"Decreases humidity from air using a substance which absorbs moisture.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^device,,,,,,,,,"Microprocessor based hardware device. This is the general term for\nall computers, mobile phones, controllers, and I/O modules.\nSee `docHaystack::Devices#networks` chapter.",,M,,,,[^entity],^lib:phIct,M,,,,,,,,,,,,,,, ^deviceRef,,,,,,,,,"Device which controls a monitors this entity",,,,,,[^ref],^lib:phIct,,,,,,,^device,,,,,,,,, ^dewPoint,,,,,,,,,"Dew point temperature at which water vapor will form dew",,,,,,[^quantity],^lib:phScience,,,,,,,,,["°C","°F"],[^air],,,,,, ^dict,,,,,,,,,"Map of name/value tag pairs.\nSee [Kinds chapter]`docHaystack::Kinds#dict`.",,,,,,[^val],^lib:ph,,,,,,,,,,,,,,,, ^diesel,,,,,,,,,"Liquid fuel specifically designed for use in diesel engines",,,,,,[^liquid],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Diesel_fuel` ^directZone,,,,,,,,,"AHU supplies air directly to the zone",,,,,,[^ahuZoneDelivery],^lib:phIoT,,,,,,,,,,,,,,,, ^direction,,,,,,,,,"Compass direction measured in degrees: North: 0° = 360°, East: 90°, South: 180°, West: 270°",,,,,,[^quantity],^lib:phScience,,,,,,,,,["deg"],,,,,,, ^dis,,,,,,,,,"Display name for an entity.\nSee `docHaystack::Ontology#entities` chapter.",,,,,,[^str],^lib:ph,,,,,,,,,,,,[^entity],,,, ^discharge,,,,,,,,,"Duct for air leaving an equipment",,,,,,[^ductSection],^lib:phIoT,,,,,,,,,,,,,,,, ^dispenser,,,,,,,,,"Equipment that releases a specific amount of a substance.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^diverting,,,,,,,,,"Three way valve which inputs one pipe and diverts between two output pipes.",,,,,,[^marker],^lib:phIoT,,,,,,,,,,,,,,,, ^doas,,,[{bypass damper cmd point},{cool cmd point},{dessicantDehumidifier cmd point},{discharge duct equip},{economizer duct equip},{economizing cmd point},{equip},{exhaust duct equip},{faceBypass cmd point},{filter sensor point},{freezeStat sensor point},{heat cmd point},{heatWheel cmd point},{humidifier equip},{hvacMode sp point},{mixed duct equip},{outside duct equip},{point},{return duct equip},{thermostat equip},{ventilation duct equip}],,,,,,"Dedicated Outside Air System: An AHU that brings in 100% outside air and\nno recirculated air in order to provide ventilation to spaces.\nSee `docHaystack::AHUs` chapter.",,,,,,[^ahu],^lib:phIoT,,,,,,,,,,,,,,,,`https://en.wikipedia.org/wiki/Air_handler` ^doc,,,,,,,,,"Documentation in simplified flavor of markdown. The first\nsentence up to the period is used as the summary.\n\nSpecific formatting options:\npre>\n// inline formatting\n*italic* // italics font\n**bold** // bold font\n'code' // code or API term\n`point` // hyperlink to def (code link)\n[text]`point` // hyperlink with explicit link text\n![alt]`image.png` // image\n\n// unordered list\n- one\n- two\n- three\n\n// ordered list; use numbers or letters\n1. one\n2. two\n3. three\n